| Peer-Reviewed

Seismic Isolation Technology Based on Green Building in Prefabricated Assembly Research Application in Structure

Received: 30 October 2021     Accepted: 13 November 2021     Published: 17 November 2021
Views:       Downloads:
Abstract

Green construction aims to provide a healthy, comfortable and efficient use of space for human beings to live in harmony with nature. The related concepts and policies of green construction are discussed, and several ways to realize green construction are introduced. Prefabricated assembly integral structure is one of the main ways of green construction. Prefabricated assembly integral structure has the characteristics of poor overall performance and weak node connection under strong earthquake. Base isolation technology is proposed to improve its seismic performance. The seismic isolation model and non-seismic isolation model of prefabricated integrated frame structure are established, and the floor shear and floor displacement of different models under various fortification intensities are compared under strong earthquakes. The favorable factors affecting the seismic performance of prefabricated structures by base isolation technology are systematically summarized.

Published in Science Discovery (Volume 9, Issue 6)
DOI 10.11648/j.sd.20210906.24
Page(s) 360-365
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2021. Published by Science Publishing Group

Keywords

Isolation Technology, Prefabrication and Assembly, Earthquake Resistant Behavior, Housing Industrialization

References
[1] GB50378-2019.中华人民共和国国家标准.绿色建筑评价标准[S].北京:中国建筑工业出版社,2019。
[2] 沈史宁.绿色建筑运动和“可维持设计”[J].华中建筑,1995(03):4-8。
[3] 张季超,楚先锋,邱剑辉,等.高效、节能、环保预制钢筋混凝土结构住宅体系及其产业化[J].工程力学,2008.12。
[4] 邱剑辉,张季超,窦祖融,等.新型装配整体式混凝土结构构造处理措施探讨[J].广州建筑,2009。
[5] 万学林,王伟,廖飞,王利文,李茂,潘忠尧.基础隔震结构受力性能研究[J].施工技术(中英文),2021,50(15):54-57。
[6] 彭凌云,苏经宇,韩流涛.我国建筑减隔震技术标准化现状与展望[J].城市与减灾,2016(05):11-18。
[7] 赵亮.橡胶隔震支座在实际工程中的应用[D].2017。
[8] GB50011—2010.中华人民共和国国家标准.建筑抗震设计规范[S].北京:中国建筑工业出版社.2016。
[9] 陈兆荣,潘东辉,魏春玲,刘波,徐新星.高层建筑框筒结构层受剪承载力计算方法研究[J].华南地震,2018,38(01):120-124。
[10] 陈兆荣,罗盛宗,潘东辉.底层大空间-单跨框架学校建筑的抗震加固分析与设计[J].建筑结构,2016,46(09):90-94。
[11] 陈晓旭,何华拓,陈兆荣.钢框架梁柱扩翼型节点的抗震性能分析[A].2015城市地下空间综合开发技术交流会论文集。
[12] JGJ297—2013.中华人民共和国行业标准.建筑消能减震技术规程[S].北京:中国建筑工业出版社,2013。
[13] 朱绪林,林明强,高蕊,高莉.中国建筑结构减隔震技术应用研究进展[J].华北地震科学,2020,38(04):86-91。
[14] 孟美莉,张德强.我国建筑物隔震与减震研究的现状与展望[J].河北建筑科技学院学报,2003(01):62-64。
[15] 杨林,刘渊,常永平,成春旺,孙付东.全球隔震支座技术专利分析[J].工程抗震与加固改造,2018,40(02):7-12。
[16] 吴崑宇.浅析建筑结构减隔震技术的应用现状与发展前景[J].福建建材,2018(5):49-50,53。
[17] 王志恒,商怀帅,魏磊,等.振动控制及减隔震技术的发展与应用[J].建筑结构,2017(S1):625-628。
[18] 刘珍.基础隔震结构体系地震反应研究[D].济南:山东大学, 2008.
[19] 张曼生,张国军,马伯涛,王明珠,张玲,刘鑫刚,葛家琪.基础隔震结构隔震层水平性能设计研究[J].建筑结构,2019,49(11):123-127+122。
[20] 陈兆荣,张季超,张建林,刘洋.某扩建工程层间隔震结构分析与设计[J].华南地震,2014,34(S1):198-203。
Cite This Article
  • APA Style

    Chen Zhaorong, Cai Zhili, Zeng Changluo, Bai Zhongkui, Du Shishuai. (2021). Seismic Isolation Technology Based on Green Building in Prefabricated Assembly Research Application in Structure. Science Discovery, 9(6), 360-365. https://doi.org/10.11648/j.sd.20210906.24

    Copy | Download

    ACS Style

    Chen Zhaorong; Cai Zhili; Zeng Changluo; Bai Zhongkui; Du Shishuai. Seismic Isolation Technology Based on Green Building in Prefabricated Assembly Research Application in Structure. Sci. Discov. 2021, 9(6), 360-365. doi: 10.11648/j.sd.20210906.24

    Copy | Download

    AMA Style

    Chen Zhaorong, Cai Zhili, Zeng Changluo, Bai Zhongkui, Du Shishuai. Seismic Isolation Technology Based on Green Building in Prefabricated Assembly Research Application in Structure. Sci Discov. 2021;9(6):360-365. doi: 10.11648/j.sd.20210906.24

    Copy | Download

  • @article{10.11648/j.sd.20210906.24,
      author = {Chen Zhaorong and Cai Zhili and Zeng Changluo and Bai Zhongkui and Du Shishuai},
      title = {Seismic Isolation Technology Based on Green Building in Prefabricated Assembly Research Application in Structure},
      journal = {Science Discovery},
      volume = {9},
      number = {6},
      pages = {360-365},
      doi = {10.11648/j.sd.20210906.24},
      url = {https://doi.org/10.11648/j.sd.20210906.24},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.sd.20210906.24},
      abstract = {Green construction aims to provide a healthy, comfortable and efficient use of space for human beings to live in harmony with nature. The related concepts and policies of green construction are discussed, and several ways to realize green construction are introduced. Prefabricated assembly integral structure is one of the main ways of green construction. Prefabricated assembly integral structure has the characteristics of poor overall performance and weak node connection under strong earthquake. Base isolation technology is proposed to improve its seismic performance. The seismic isolation model and non-seismic isolation model of prefabricated integrated frame structure are established, and the floor shear and floor displacement of different models under various fortification intensities are compared under strong earthquakes. The favorable factors affecting the seismic performance of prefabricated structures by base isolation technology are systematically summarized.},
     year = {2021}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Seismic Isolation Technology Based on Green Building in Prefabricated Assembly Research Application in Structure
    AU  - Chen Zhaorong
    AU  - Cai Zhili
    AU  - Zeng Changluo
    AU  - Bai Zhongkui
    AU  - Du Shishuai
    Y1  - 2021/11/17
    PY  - 2021
    N1  - https://doi.org/10.11648/j.sd.20210906.24
    DO  - 10.11648/j.sd.20210906.24
    T2  - Science Discovery
    JF  - Science Discovery
    JO  - Science Discovery
    SP  - 360
    EP  - 365
    PB  - Science Publishing Group
    SN  - 2331-0650
    UR  - https://doi.org/10.11648/j.sd.20210906.24
    AB  - Green construction aims to provide a healthy, comfortable and efficient use of space for human beings to live in harmony with nature. The related concepts and policies of green construction are discussed, and several ways to realize green construction are introduced. Prefabricated assembly integral structure is one of the main ways of green construction. Prefabricated assembly integral structure has the characteristics of poor overall performance and weak node connection under strong earthquake. Base isolation technology is proposed to improve its seismic performance. The seismic isolation model and non-seismic isolation model of prefabricated integrated frame structure are established, and the floor shear and floor displacement of different models under various fortification intensities are compared under strong earthquakes. The favorable factors affecting the seismic performance of prefabricated structures by base isolation technology are systematically summarized.
    VL  - 9
    IS  - 6
    ER  - 

    Copy | Download

Author Information
  • China Construction Fifth Engineering Bureau the Third Construction Co., Ltd. Changsha, China

  • China Construction Fifth Engineering Bureau the Third Construction Co., Ltd. Changsha, China

  • China Construction Fifth Engineering Bureau the Third Construction Co., Ltd. Changsha, China

  • China Construction Fifth Engineering Bureau the Third Construction Co., Ltd. Changsha, China

  • China Construction Fifth Engineering Bureau the Third Construction Co., Ltd. Changsha, China

  • Sections